In warm seasons like this one, my thoughts sometimes turn to DIY air conditioning (AC). In our climate, AC is one of those rarely-needed things so buying some off-the-shelf solution doesn't appear to be a very cost effective solution. I'd much rather spend lots more time and less money on something that works well enough to take the edge off the heat when it occasionally occurs. I've seen approaches using evaporative cooling, but our climate also has an additional challenge -- relatively high humidity. So-called "swamp coolers" work best in regions where the relative humidity is low. They're more efficient, and the added moisture to the air is welcome. On the other hand, when you start with 60% relative humidity, the cooling action isn't as good: and the increased humidity due to the swamp cooler can actually make you LESS comfortable, even if the temperature is slightly lower.
There are indirect cooling approaches where a heat exchanger comes into play, cooling inside air without adding moisture. The heat exchanger is an added complexity, and also has its own impact on efficiency. What if we could start with much-cooler water, cooler than can be achieved using evaporative cooling? If we can get that, perhaps we can live with less-than-perfect heat exchanger technology.
There may be a way to do this.
Long ago I performed an experiment to see if it would be possible to make my own
turbomolecular vacuum pump (I refer you to Google to get educated on this type of vacuum pump). I mounted two thin mylar plastic disks on an
axle. They were spaced a few tenths of an inch apart. Then I spun
them up, using either a Dremel tool or an electric drill (this WAS a
long time ago so I don’t remember that part all that clearly).
Centrifugal force would pull the disks into flat planes, but, if some
pumping action were taking place, the space between the disks would
be at a lower pressure so the disks would be pushed together. I
observed that the disks were indeed pushed toward each other so some pumping action was going on. I
could not increase the speed enough to get the disks to touch, due to
instability and vibration problems, but this problem probably could be solved with some refinement.
If the axle was made from a
tube, and we drilled some holes in it between the two disks, it is
likely that some sort of pumping action would occur that would pull
gas down the tube toward the disks: but now we’re faced with
making a good rotary seal. The angular velocity of the tube would be
less than the outer edges of the disks, but it still is a nontrivial
problem if you want a reliable vacuum pump.
So that approach
languished for a long time. But I recently had an idea where the
scheme could still be useful. As a chiller. In point of fact, it
would function as a single-pass refrigeration system. In this
approach, the spinning tube is dipped into a water reservoir. The tube also
has a restrictor to reduce the water flow so the water doesn’t
completely fill the pump. If the water does fill the pump, I
believe the water probably will boil in the disk portion of the pump and screw
up the cooling cycle (see below). If sufficient vacuum is developed
the water will boil, extracting heat from its surroundings. The
water vapor is ejected by the spinning disk pump, where it
immediately re-condenses (and liberates the heat it absorbed when it
boiled).
In its simplest
form, the rotating tube would be submerged in the water so the
expansion of liquid water into water vapor would cool the water on
the immediate exterior of the tube, which could then be circulated
into a secondary heat exchanger. Efficiency could be improved by
increasing the surface area of the submerged tube, perhaps with
aluminum or copper disks (but they can’t be too large or frictional
forces would limit the maximum RPM, and also heat the water).
The advantage of
this method is that the minimum-achievable temperature is not
determined by the relative humidity of air, unlike a standard
evaporative air conditioner. The minimum temperature would be the
freezing point of water (0C/32F).
NOTE: this scheme
could be foiled by the buildup of minerals from the water feedstock, since the minerals would be concentrated by the liquid-vapor conversion. Some type of purge or ballast-water approach would be needed for a commercially viable system.
Also NOTE: while
one might think the water vapor exiting the pump would be cold &
therefore useful for cooling purposes, in fact it will re-condense as
soon as its pressure returns to room pressure. When
this happens, it will release the heat it absorbed. Now, of course, the water will
be very finely dispersed and some to all of it will evaporate in the ambient air –
again cooling down in the process. But there won’t be any “gain”
offered by the pump, and the ultimate minimum-low temperature will
be determined by the dew point of the ambient air – much higher
than the freezing point of water.
So it appears the energy input of the spinning-disk scheme is best used as a way to implement a single-pass refrigeration system. I use the term "single-pass" because the input fluid, water, is available without any special condensor. Unlike a classic closed-system refrigeration system.